1、 AIR POLLUTANTSTYPES OF AIR CLEANING EQUIPMENT.http:/e-stud.vgtu.lt/darb/3142.Listed below are the major air pollutants and their sourcesCarbon monoxide(CO)Carbon dioxide(CO2)Chloroflorocarbons(CFC)Lead(Pb)Nitrogen oxide(Nox)Suspended particulate matter(SPM)Sulphur dioxide(SO2).Men and the environme
2、nt4Fine Particulate Matter(PM2.5)nEXAMPLES OF SOURCES:nFuel combustion in motor vehicles,equipment,and industrial sources;residential and agricultural burning.Also formed from reaction of other pollutants(acid rain,NOx,SOx,organics).Particulate Matter(PM10:less than or equal to 10 microns)nEXAMPLES
3、OF SOURCES:nCars and trucks,especially diesels nFireplaces,woodstoves nWindblown dust,from roadways,agriculture and construction .Dust storm approaching Stratford,Texas.Ozone(O3)nEXAMPLES OF SOURCES:nFormed by chemical reactions of air pollutants in the presence of sunlight.Common sources:motor vehi
4、cles,industries,and consumer products .Men and the environment8Carbon Monoxide(CO)nEXAMPLES OF SOURCES:nAny source that burns fuel such as cars,trucks,construction and farming equipment,and residential heaters and stoves .Men and the environment9Nitrogen Dioxide(NO2)nEXAMPLES OF SOURCES:n Chest pain
5、 in heart patients nHeadaches,nausea nReduced mental alertness nDeath at very high levels .Burnig Field in Georgia.Men and the environment11Toxic Air Contaminants nEXAMPLES OF SOURCES:nCars and trucks,especially diesels nIndustrial sources such as chrome platers nNeighborhood businesses,such as dry
6、cleaners and service stations nBuilding materials and products .Air pollution from factories.Emission is increasing every year.Men and the environment13Lead nEXAMPLES OF SOURCES:nMetal smelters,resource recovery,leaded gasoline,deterioration of lead paint.Men and the environment14Sulfur Dioxide(SO2)
7、nEXAMPLES OF SOURCES:nCoal or oil burning power plants and industries,refineries,diesel engines.Men and the environment16Visibility Reducing Particles nEXAMPLES OF SOURCES:nFuel combustion in motor vehicles,equipment,and industrial sources;residential and agricultural burning.Smog in China in August
8、 2005.Looking down from the Hollywood Hills,with Griffith Observatory on the hill in the oreground,air pollution is visible in downtown Los Angeles on a late afternoon.Men and the environment19Sulfates nEXAMPLES OF SOURCES:nProduced by the reaction in the air of SO2,a component of acid rain.Hydrogen
9、 Sulfide nEXAMPLES OF SOURCES:nGeothermal power plants,petroleum production and refining,sewer gas.HEALTH EFFECTS nIncreased respiratory disease nLung damage nPremature death nCancer nChronic eye,lung,or skin irritation nNeurological and reproductive disorders .Prevention and Control nReduce motor v
10、ehicle reactive organic gas(ROG),volatile organic compounds(VOC)and nitrogen oxide emissions through emissions standards,reformulated fuels,inspections programs,and reduced vehicle use.Limit ROG emissions from commercial operations and consumer products.Limit ROG and NOx emissions from industrial so
11、urces such as power plants and refineries.Conserve energy nControl dust sources,industrial particulate emissions,wood burning stoves and fireplaces.Reduce secondary pollutants which react to form PM10.Conserve energy nControl emissions from geothermal power plants,petroleum production and refining,s
12、ewers,sewage treatment plants.Pollution control hardware,technologies and equipment that may be applicable to pollution prevention opportunities.METHODS OF PARTICULATE COLLECTIONMETHODS FOR CLEANING GASEOUS POLLUTANTS.METHODS OF PARTICULATE COLLECTIONSettling chambers,low-pressure-drop cyclones,and
13、dynamic precipitators are among the most common and important devices applied in end-of-pipe control applications for dust and particulate matter.GRAVITY SETTLING CHAMBERSRemoval of air pollutants through the mechanism of downward gravitational forces.In principle,pollutants are removed by reducing
14、the velocity of the gas stream sufficiently to allow particles to settle out under the influence of gravity.The simplest chamber is merely a horizontal duct in which large particles settle out on the floor.High-efficiency settling chambers are often fitted with baffles or deflectors to change the ga
15、s flow direction.This type of technology is a part of the group of air pollution ontrols collectively referred to as precleaners“.Particle ClassificationBefore selecting or sizing a specific control device,a careful evaluation of all aspects of the process and contaminants must be made.Liquid in Gas
16、Solid in Gas.Liquid in Gas:These include the following terminology:Mists and Sprays-There are numerous industrial chemical operations which involve liquid-in-gas dispersions.These operations generate mists and sprays that consist of particles in diameter ranges of:0.1 to 5,000 m.Liquid in Gas.Dusts-
17、Dusts are fine solid particles often formed in such operations aspulverizing,crushing,grinding,drilling,detonation,and polishing.Otherindustrial sources are conveying operations and screening.Particle diameters generally are in the range of 1.0 to 1,000 m.Dusts generally do not diffuse in air,but se
18、ttle out by gravity.Flyash-Flyashes are fiiely divided matter generally entrained in flue gases that arise from combustion.Particles range from 1 m in size on down.This is not within the operational range of gravity settling chambers.Wet scrubbers are generally employed in flyash control.In some app
19、lications high-efficiency electrostatic precipitators,baghouses,or cyclones are utilizedSolid in Gas.Fumes-Fumes are finely divided solid particles that are generated by thecondensation of vapors.Fumes are generated by sublimation,distillation,and molten metal processes.Particle diameters are genera
20、lly in the range of 0.1 to 1 m.Smoke-Smoke constitutes fine,solid,gasborne matters that are products ofincomplete combustion of organics(wood,coal,tobacco).Smoke particlesare extremely small,ranging in size from less than 0.01 m to 1 m.Solid in Gas.Smog-Smog refers to a mixture of natural fog and in
21、dustrial smoke.Aerosols-Aerosols are an assemblage of small particles,either solid orliquid,suspended in gas.Particle sizes range from 0.01 to 100 m.There are several classes of aerosols.Dispersion aerosols are a common class that are formed from processes such as grinding.Condensation aerosols are
22、formed when supersaturated vapors condense or when gases react chemically to form a nonvolatile product.Grit-The term grit is used to classify coarse particles that are are normally greater than 43 m in diameter and are within the operating efficiency of gravity settling chambers.Solid in Gas.Horizo
23、ntal simple gravity settling chamberAs a general guideline,linear gas velocities are kept below 300 cm/sec.This is satisfactory for most materials;however,some low-density particulates are reentrained at lower velocities.Most designs only effectively collect PM greater than approximately 50 m.Emissi
24、on Stream CharacteristicsAir Flow:The simple design and construction of settling chambers allows for almost any size and waste gas flow rate.Usualy flow rates range up to 50 m3/secTemperurure:Inlet gas temperatures are only limited by the materials ofconstruction of the settling chamber,and have bee
25、n operated at temperatures as high as 600 C.Pollutant Loading:Waste gas pollutant loadings can range from 20 to 4500 g/m3.Other Considerations:Leakage of cold air into a settling chamber can cause local gas condensation.Condensation can cause corrosion,dust buildup and plugging of the hopper or dust
展开阅读全文